ZTK(P) Variable Frequency Control System
The ZTK(P) non-explosion-proof mine hoisting electrical control system is suitable for single-rope winding dock cableway hoists (winches) or single-rope winding mine hoists (winches) driven by AC variable-frequency motors, as well as multi-rope friction mine hoists (winches).
Category:
Mining electrical equipment
Keywords:
Contact Us
Need help? We’re here for you anytime!
Phone
+86 18739238888
hbshuangmin@aliyun.com
Contact Address
Shilin Industrial Park, Shan District, Hebi City, Henan Province
Previous item
Next one
Uses and Scope of Application
The ZTK(P) non-explosion-proof mine hoisting control system is suitable for single-rope winding dock cableways or single-rope winding mine hoists (winches) driven by AC variable-frequency motors, as well as multi-rope friction mine hoists (winches). It can be used with newly installed hoists (winches) and is also ideal for retrofitting existing hoist (winch) electrical control systems.
Technical Parameters
Electrical Control Technical Parameters |
Control |
Control method |
Space Voltage Vector Control Method |
|||||||
Frequency setting resolution |
Digital: 0.01 Hz (below 100 Hz) 0.1 Hz (below 100 Hz) Simulation: 0.5 Hz Output frequency range: 0-300 Hz |
|||||||||
Frequency accuracy |
Digital: 0.01% of the maximum output frequency; Analog: 0.1% of the maximum output frequency |
|||||||||
V/F ratio |
Linear: Square root, any V/F |
|||||||||
Overload capacity |
Rated current: 150% for 1 minute; Rated current: 200% for 0.5 second (characteristic is directly proportional to time). |
|||||||||
Torque compensation |
Manual torque compensation (0-20%) Automatic torque compensation |
|||||||||
Run |
Input signal |
Operating method |
Keyboard/Terminal/RS485 Communication |
|||||||
Frequency resolution |
Simulation: 0-10V/4-20mA/Additional interface on the daughter board (0-10V, 4-20mA) |
|||||||||
Start signal |
Digital: Keyboard/RS485 Communication |
|||||||||
Main story / Reverse |
||||||||||
Acceleration and Deceleration Time |
0–6000 seconds: Acceleration and deceleration time is switchable. |
|||||||||
Deceleration mode: Linear S-shaped |
||||||||||
Emergency stop |
Interrupt the inverter's output |
|||||||||
Inch movement |
Slow-speed operation |
|||||||||
Fault reset |
When the protection function is enabled, the fault state can be automatically reset. |
|||||||||
Output signal |
Operating status |
Frequency detection level, overload alarm, overvoltage, undervoltage, inverter overheating, running, stopping, constant speed |
||||||||
Fault output |
Contact output – AC 250V 1A, DC 30V 1A |
|||||||||
Analog output |
Select from output frequency, output current, output voltage, and DC voltage (output voltage: 0–10V). |
|||||||||
Protection function |
Run function |
DC braking, frequency limitation, frequency hopping, slip compensation, reverse rotation protection |
||||||||
Inverter protection |
Overvoltage, undervoltage, overcurrent, blown fuse, ground fault, inverter failure, motor overheating, phase loss, overload protection, external fault 1.2, communication error, speed command loss, hardware failure, incorrect option, etc. |
|||||||||
Inverter alarm |
Protection blocked, overload alarm, temperature sensor malfunction |
|||||||||
Power outage in an instant |
Less than 15 milliseconds: Continuous operation |
|||||||||
Greater than 15 milliseconds: Automatic restart allowed |
||||||||||
Display |
keyboard |
Operating Information |
Output frequency, output current, output voltage, set frequency, operating speed, DC voltage |
|||||||
Error message |
When operating in fault protection mode, 3 fault duration records are saved. |
|||||||||
|
Ambient temperature |
-10℃ to 40℃ |
||||||||
|
Storage temperature |
-20℃ to 65℃ |
||||||||
|
Environmental humidity |
Maximum 90% RH (no condensation) |
||||||||
|
Height/Vibration |
Below 1000 m, below 5.9 m/s (=0.6 g) |
||||||||
|
Application location |
Non-corrosive gases, flammable gases, oil mist or dust, and others |
||||||||
Cooling method |
Forced air cooling |
|||||||||
Electrical control equipment is suitable for the following applicable locations (please specify if ordering for environments beyond those listed below).
1) The altitude should not exceed 1,000 meters. If the altitude exceeds this threshold, components should be operated at reduced power and capacity levels in proportion to the increase in altitude, and safety parameters such as the minimum safe creepage distance for certain components should also be taken into account.
2) The ambient temperature shall not exceed 40℃ nor fall below 0℃.
3) Relative humidity not exceeding 85%;
4) No conductive dust or gases that can damage metals and insulators;
5) No severe vibrations and a tilt angle no greater than 5°;
6) No strong magnetic field is present;
7) Areas that do not require explosion-proof protection;
8) The applicable premises can be met after taking the necessary measures;
9) Applications in special locations must be custom-ordered and must be specified in the technical agreement.
Scope of application
Dock cableways, mine main shaft hoisting systems with single-level and multi-level operations, auxiliary shaft hoisting systems with single-level and multi-level operations, as well as single-layer and double-layer cage systems.