ZTK(P) Variable Frequency Control System

The ZTK(P) non-explosion-proof mine hoisting electrical control system is suitable for single-rope winding dock cableway hoists (winches) or single-rope winding mine hoists (winches) driven by AC variable-frequency motors, as well as multi-rope friction mine hoists (winches).

Category:

Mining electrical equipment

Contact Us

Need help? We’re here for you anytime!

Phone

+86 18739238888


Email

hbshuangmin@aliyun.com


Contact Address

Shilin Industrial Park, Shan District, Hebi City, Henan Province

Next one

Uses and Scope of Application

The ZTK(P) non-explosion-proof mine hoisting control system is suitable for single-rope winding dock cableways or single-rope winding mine hoists (winches) driven by AC variable-frequency motors, as well as multi-rope friction mine hoists (winches). It can be used with newly installed hoists (winches) and is also ideal for retrofitting existing hoist (winch) electrical control systems.

 

Technical Parameters

Electrical Control Technical Parameters

Control

Control method

Space Voltage Vector Control Method

Frequency setting resolution

Digital: 0.01 Hz (below 100 Hz) 0.1 Hz (below 100 Hz)

Simulation: 0.5 Hz Output frequency range: 0-300 Hz

Frequency accuracy

Digital: 0.01% of the maximum output frequency; Analog: 0.1% of the maximum output frequency

V/F ratio

Linear: Square root, any V/F

Overload capacity

Rated current: 150% for 1 minute; Rated current: 200% for 0.5 second (characteristic is directly proportional to time).

Torque compensation

Manual torque compensation (0-20%) Automatic torque compensation

Run

Input signal

Operating method

Keyboard/Terminal/RS485 Communication

Frequency resolution

Simulation: 0-10V/4-20mA/Additional interface on the daughter board (0-10V, 4-20mA)

Start signal

Digital: Keyboard/RS485 Communication

Main story / Reverse

Acceleration and Deceleration Time

0–6000 seconds: Acceleration and deceleration time is switchable.

Deceleration mode: Linear S-shaped

Emergency stop

Interrupt the inverter's output

Inch movement

Slow-speed operation

Fault reset

When the protection function is enabled, the fault state can be automatically reset.

Output signal

Operating status

Frequency detection level, overload alarm, overvoltage, undervoltage, inverter overheating, running, stopping, constant speed

Fault output

Contact output – AC 250V 1A, DC 30V 1A

Analog output

Select from output frequency, output current, output voltage, and DC voltage (output voltage: 0–10V).

Protection function

Run function

DC braking, frequency limitation, frequency hopping, slip compensation, reverse rotation protection

Inverter protection

Overvoltage, undervoltage, overcurrent, blown fuse, ground fault, inverter failure, motor overheating, phase loss, overload protection, external fault 1.2, communication error, speed command loss, hardware failure, incorrect option, etc.

Inverter alarm

Protection blocked, overload alarm, temperature sensor malfunction

Power outage in an instant

Less than 15 milliseconds: Continuous operation

Greater than 15 milliseconds: Automatic restart allowed

Display

keyboard

Operating Information

Output frequency, output current, output voltage, set frequency, operating speed, DC voltage

Error message

When operating in fault protection mode, 3 fault duration records are saved.

 

Ambient temperature

-10℃ to 40℃

 

Storage temperature

-20℃ to 65℃

 

Environmental humidity

Maximum 90% RH (no condensation)

 

Height/Vibration

Below 1000 m, below 5.9 m/s (=0.6 g)

 

Application location

Non-corrosive gases, flammable gases, oil mist or dust, and others

Cooling method

Forced air cooling

 

Electrical control equipment is suitable for the following applicable locations (please specify if ordering for environments beyond those listed below).

1) The altitude should not exceed 1,000 meters. If the altitude exceeds this threshold, components should be operated at reduced power and capacity levels in proportion to the increase in altitude, and safety parameters such as the minimum safe creepage distance for certain components should also be taken into account.

2) The ambient temperature shall not exceed 40℃ nor fall below 0℃.

3) Relative humidity not exceeding 85%;

4) No conductive dust or gases that can damage metals and insulators;

5) No severe vibrations and a tilt angle no greater than 5°;

6) No strong magnetic field is present;

7) Areas that do not require explosion-proof protection;

8) The applicable premises can be met after taking the necessary measures;

9) Applications in special locations must be custom-ordered and must be specified in the technical agreement.

 

Scope of application

Dock cableways, mine main shaft hoisting systems with single-level and multi-level operations, auxiliary shaft hoisting systems with single-level and multi-level operations, as well as single-layer and double-layer cage systems.